Skip to content
systemcoding.dev
Mainframe

Read a root segment with a GU call

Read one IMS root segment by key with a GU call to CBLTDLI and a qualified SSA, then check the PCB status code, in Enterprise COBOL 6.4.

1 min read
Summarize in AI

GU (get unique) fetches a specific segment from the top of the database, so it is the call for a keyed lookup.

cobol
01  DLI-GU        PIC X(4) VALUE 'GU  '.
01  CUST-SSA.
    05  FILLER    PIC X(8)  VALUE 'CUSTOMER'.
    05  FILLER    PIC X     VALUE '('.
    05  FILLER    PIC X(8)  VALUE 'CUSTKEY '.
    05  FILLER    PIC XX    VALUE ' ='.
    05  SSA-KEY   PIC X(5).
    05  FILLER    PIC X     VALUE ')'.
...
MOVE '00042' TO SSA-KEY.
CALL 'CBLTDLI' USING DLI-GU DB-PCB CUST-IO-AREA CUST-SSA.

The call passes the function code, the database PCB, an I/O area for the segment and the SSA. The function code is four bytes, so GU has two trailing blanks. A status code of two blanks in DB-PCB means success, and GE means no segment matched.

A qualified SSA has the segment name in 8 bytes, then (, an 8-byte field name, a 2-byte operator such as = with a leading blank, the value, and ). A wrong length shifts every later field and gives status AJ (invalid SSA). On a root with a unique key, GU is direct, while a non-unique field needs a scan. This is the DL/I interface in IMS 15.

Taggedcobolims