Generate a testbench clock with always (#5 clk = ~clk)
Drive a 100 MHz testbench clock with a one-line always block, and see why the initial value and the timescale decide whether it works.
The shortest testbench clock is one line, and it needs two things around it. The always block inverts clk every 5 time units, so the period is 10. The register must start at a known value, because an x inverted is still x and the clock never ticks.
`timescale 1ns/1ps
module tb;
reg clk = 1'b0;
always #5 clk = ~clk;
initial begin
repeat (3) @(posedge clk) $display("posedge at %0d ns", $time);
$finish;
end
endmoduleposedge at 5 ns
posedge at 15 ns
posedge at 25 nsThe simulator also prints its own finish line after $finish, which varies by tool. With 1ns/1ps the #5 means 5 ns, so the period is 10 ns, a 100 MHz clock. The first rising edge comes at 5 ns because the register starts low and the first toggle is a rise.
Without a timescale directive the delay unit depends on the tool's default, and Icarus Verilog 12 uses 1 s. That does not change the edge ordering, but the times you read in a waveform mean nothing. For an odd period, such as 12 MHz, write the half period in the right unit, for example #41.667 under 1ns/1ps, since integer delays truncate to the time unit.